beautypg.com

System power consumption, Heat dissipation, Environmental specifications – H3C Technologies H3C S12500-X Series Switches User Manual

Page 98: Noise

background image

90

System power consumption

The system power consumption of the switch depends on the type and number of cards and the fan tray

power consumption.

The minimum system power consumption is the total static power consumption of all cards plus the
minimum fan tray power consumption.

The maximum system power consumption is the total dynamic power consumption of all cards plus
the maximum fan tray power consumption.

For example, for an S12510-X AC switch that has two LSX1SUP10A1 MPUs, two LSX1TGS48EA1 LPUs,

six LSX1FAB10B1 switching fabric modules, and two S12510-X fan trays, the minimum system power

consumption of the switch is 2 × 45 + 2 × 310+ 6 × 135 + 2 × 196= 1912 W, and the maximum system

power consumption of the switch is 2 × 50 + 2 × 435 + 6 × 170 +2 × 1377 = 4744 W.

Heat dissipation

Heat dissipation is measured in BTU/h, and 1 W equals 3.4121 BTU/h.
The heat dissipation of a switch depends on its power consumption. To calculate heat dissipation of the

switch, assume 90% power consumption is converted to heat, and the efficiency of the power module is
90%. Heat dissipation/hour of the switch is 0.9 × (total power consumption of the cards plus power

consumption of the fan tray)/0.9 × 3.4121.
For the power consumption of the cards and fan trays of the H3C S12500-X switches, see "

Module

power consumption and system power consumption

."

Environmental specifications

Table 22 Environmental specifications

Description Operating

Non-operating

Temperature

0°C to 45°C (32°F to 113°F)

–40°C to +70°C (–40°F to +158°F)

Relative humidity
(noncondensing)

5% to 95%

5% to 95%

Noise

The switch uses fans with the automatic speed adjustment function, so the sound pressure levels vary by

fan speed. For more information, see

Table 23

.

Table 23 Sound pressure levels

Model

Sound pressure level under

normal temperature

Sound pressure level when the

fan tray operates at full speed

S12510-X AC (two fan trays)

S12510-X DC (two fan trays)

67.7 dBA

83.9 dBA