beautypg.com

15 maintenance / diagnostics / repairs, 1 error messages, 2 troubleshooting – ARAG Navigator LT User Manual

Page 63: 3 cleaning rules, Maintenance / diagnostics / repairs

background image

63

15

MAINTENANCE / DIAGNOSTICS / REPAIRS

15.1

Error messages

MESSAGE ON DISPLAY

CAUSE

REMEDY

GPS receiver not connected!

Wrong connection of receiver cable to Navigator

• Check connection to receiver

(par. 5.2).

The receiver connection cable is damaged

• Replace the cable.

The receiver is damaged

• Replace the receiver.

Insufficient GPS signal quality!

The position and number of satellites do not allow a
suitable driving precision

• Wait for signal strength to improve.

GPS receiver gives invalid data!

The receiver is establishing a connection to the
satellites

• Wait for connection.

DGPS correction not available!

DGPS signal unavailable in the working area

• Disable DGPS correction

(par. 10.2.1).

DGPS connecting

• Wait for connection.

Job origin too far away!

The current position is too far away from the job origin. • Redefine the job origin.

15.2

Troubleshooting

FAULT

CAUSE

REMEDY

The display does not switch on

No power supply

• Check power supply connection.

Computer is OFF

• Press the ON key.

Speed reading is unstable

Job start procedure was launched at a point too far from
the field to be sprayed

• Start a new job

(par. 11.4) close to the field.

Distance traveled count displayed does not
match actual distance covered

Wrong setup

• Check the boom setup

(par. 10.1.1).

• Check implement geometry

(par. 10.1.3 - 10.1.4).

• Check tractor geometry

(par. 10.2.9).

15.3

Cleaning rules

- Clean only with a soft wet cloth.
- DO NOT use aggressive detergents or products.
- Do not clean the monitor with direct water jets.

MAINTENANCE / DIAGNOSTICS / REPAIRS