AEC HE Mass Flow Series Drying hoppers User Manual
Page 47

Page 46
HE
• CHE • BCHE Mass Flow Series Drying Hoppers
Figure 17
Available Option Boards
Option type
RS232C
RS-485
Event input
Transfer output
Board no.
E53-CK01 E53-CK03 E53-CKB
E53-CKF
Notes:
• Option Mode only visible when an option board is installed.
• Use default settings for Communications board. Contact AEC Whitlock Engineering
for settings on “Event Input” and “Transfer Output” boards.
Mode
Parameter
Setting range
Default
AEC setting
Option
Eu-A Multi-SP Function
0/1
0
Default
Option
Eu-1 Event Input Assign 1
STOP/MAN
STOP
Default
Option
SbCE Communication Stop Bit
½ BITS
2
Default
Option
LEn Comm. Data Length
7/8 BITS
7
Default
Option
PrEY Communication Parity
None/Even/Odd
Even
Default
Option
6PS Comm. Baud Rate
1.2/2.4/4.8/9.6/19.2
9.6 kbps
Default
Option
U-n6 Comm. Unit No.
0 to 99
0
Default
Option
Er-E Transfer Output Type
SP/SP-M/PV/O/C-O
SP
Default
Option
Er-H Xfer Output Upper Limit
5
5
Default
Option
Er-L Xfer Output Lower Limit
5
5
Default