Sv out1 out2 manu stop rmt at sub1 a m – AEC HE Mass Flow Series Drying hoppers User Manual
Page 38
HE
• CHE • BCHE Mass Flow Series Drying Hoppers
Page 37
Figure 14
1/16 DIN Controller
PV
SV
OUT1
OUT2 MANU STOP RMT
AT
SUB1
A
M
Identifying Temperature Controller LED Indicators on the 1/16 DIN
Controller
PV (Process Value) Numeric LED
During normal operation, the process value (
PV
) numeric LED indicator displays the process
temperature at the To Process thermocouple. It also lists parameters during setup and error
messages if any errors occur.
SV (Set Value) Numeric LED
During normal operation, the set value (
SV
) numeric LED indicator displays the process set
point you selected for the dryer. The dryer then maintains this set point temperature. This LED
indicator also displays parameter and pre-set function values during setup.
OUT1
The
OUT1
indicator lights when the controller transmits an energize signal to process heaters.
Process value
(PV) indicator
Set value (SV)
indicator
Automatic
tuning (AT)
indicator
SUB1 indicator
Up key
Down key
OUT1
indicator
MANU (Manual)
indicator
STOP
indicator
Auto/Manual
key
Display
key
OUT2 indicator
RMT (Remote)
indicator