AEC HE Mass Flow Series Drying hoppers User Manual
Page 42

HE
• CHE • BCHE Mass Flow Series Drying Hoppers
Page 41
Level 1 Mode
For adjusting primary control parameters. Execute:
AT
(auto-tuning); set alarm values; set the
control period; set PID parameters.
Level 2 Mode
For adjusting secondary control parameters. Nomad Cart uses E5CK default settings.
Setup Mode
For setting the basic specifications. Set parameters for input type, scaling, output assignments
and direct/reverse operation.
Expansion Mode
For setting expanded functions. Set:
ST
(self-tuning), SP setting limiter. Select: advance PID or
ON/OFF
control.
Option Mode
This mode is only accessible when and option board is installed.
Calibration Mode
For calibrating communication unit E53-CKF. Not used.
A
M
A/M Key
Protect Mode
Limits the use of the menu and
A
M
Automatic/Manual keys. The protect function allows for
setting different levels of security. See
Setting E5CK Security in Protect Mode
on the
following page for E5CK security settings.
Manual Mode
Sets the controller to manual operation mode. Nomad carts are set for manual mode.