AEC HE Mass Flow Series Drying hoppers User Manual
Page 46

HE
• CHE • BCHE Mass Flow Series Drying Hoppers
Page 45
Figure 16
Default Setting List for 1/16 DIN Process Temperature Controller
Mode
Parameter
Setting range
Default AEC setting
Setup
Cn-E Input Type
0 to 21
2
3
Setup Cn-H Scaling Upper Limit
Scaling Lower Limit +1 to 9999 EU
-100
Default
Setup Cn-L Scaling Lower Limit
-1999 to SP Setting Upper Limit -
0.1 EU
0 Default
Setup
dP Decimal Point
0 to 3
0
Default
Setup
d-U °C/F Selection
°C/F
°C
°F
c
Setup CnCE Parameter Initialize
Yes/No
No
Default
Setup
6UE1 Control Output 1
Assignment
Heat/Cool/Alarm 1/ Alarm 2/Alarm
3/LBA
Heat Default
Setup
6UE2 Control Output 2
Assignment
Heat/Cool/Alarm 1/ Alarm 2/Alarm
3/LBA
AL-1 Default
Setup
Sub 1 Auxiliary Output 1
Assignment
Alarm 1/Alm 2/Alm 3/LBA/S.
ERR/E333
AL-2 Default
Setup
ALE1 Alarm 1 Type
0 to 11
2
Default
Setup
AL1n Alarm 1 open in
alarm
NO/NC NO
Default
Setup
ALE2 Alarm 2 Type
0 to 11
2
Default
Setup
AL2n Alarm 2 open in
alarm
NO/NC NO
Default
Setup
ALE3 Alarm 3 Type
0 to 11
2
Default
Setup
AL3n Alarm 3 open in
alarm
NO/NC NO
Default
Setup
6rEu Direct/Reverse
Operation
OR-R/OR-D OR-R
Default
c Check sales order for temperature unit selection.
Mode
Parameter
Setting range
Default AEC setting
Expansion
SL-H Set Point Upper Limit
SP Lower Limit +1 to
Scaling Upper Limit
1300 400.0
Expansion
SL-L Set Point Lower Limit
Scaling Upper Limit to SP
Lower Limit
-200 0
Expansion CnEL
PID/ON/OFF
PID/ON/OFF
PID
Default
Expansion SE ST Adaptive Tuning (Fuzzy)
OFF/ON
OFF
Default
Expansion
SE-b ST Stable Range
0.1 to 999.9 °C/F
15
Default
Expansion
ALFA
α
0.01 to 1.00
0.65
Default
Expansion
AE-G AT Calculated Gain
0.1 to 10.0
1.0
Default
Expansion
rESE Standby Sequence Reset
Setting Method
0/1 0
Default
Expansion
rEE Automatic Return of
Display Mode
0 to 99 SEC
0
Default
Expansion
AE-H AT Hysteresis
0.1 to 9.9 %FS
0.2
Default
Expansion
LbAb LBA Detection Width
0.0 to 999.9 %FS
0.2
Default