Command Lines of the Warning configuration
Feature
Command Line
Relay Output
Relay Output
Switch(config)# relay 1
dry dry output
ping ping failure
port port link failure
power power failure
ring super ring failure
Note: Select Relay 1 or 2 first, then select the
event types.
Dry Output
Switch(config)# relay 1 dry
<0-4294967295> turn on period in second
Switch(config)# relay 1 dry 5
<0-4294967295> turn off period in second
Switch(config)# relay 1 dry 5 5
Ping Failure
Switch(config)# relay 1 ping 192.168.2.200
reset reset a device
Switch(config)# relay 1 ping 192.168.2.200 reset
<1-65535> reset time
Switch(config)# relay 1 ping 192.168.2.200 reset
60
<0-65535> hold time to retry
Switch(config)# relay 1 ping 192.168.2.200 reset
60 60
Port Link Failure Switch(config)# relay 1 port
PORTLIST port list
Switch(config)# relay 1 port fa1-5
Power Failure
Switch(config)# relay 1 power
<1-2> power id
any Anyone power failure asserts relay
Switch(config)# relay 1 power 1
Super Ring Failure Switch(config)# relay 1 ring
Disable Relay
Switch(config)# no relay
<1-2> relay id