Westermo MDI-112-F4G User Manual
Page 136
132
4.11.2 Event Selection
Event Types can be divided into two basic groups: System Events and Port Events.
System Events are related to the overall function of the switch, whereas Port
Events related to the activity of the specific ports
System Event
Warning Event is sent when…..
Authentication Failure An incorrect password, SNMP Community String
is entered.
Time Synchronize
Failure
Accessing to NTP Server is failure.
Power 1 Failure
Selected Power ID is failure.
Power 2 Failure
Selected Power ID is failure.
Fault Relay
The DO/Fault Relay is on.
Super Ring Topology
Changes
Master of Super Ring has changed or backup
path is activated.
Port Event
Warning Event is sent when…..
Link-Up
The port is connected to another device
Link-Down
The port is disconnected (e.g. the cable is pulled
out, or the opposing devices turns down)
Both
Either of Link Up or Link Down