Configuration of fxo – Welltech ePBX-100A-128 User Manual
Page 95
![background image](https://www.manualsdir.com/files/809449/content/doc095.png)
95
Set Account and Password for 3804A
•
If all of the above settings are correct, you can go to Information
Æ Subscriber page to confirm
the register status.
•
There are also some other necessary configuration of 3804A to compatible with ePBX-100A-128.
But these settings do not exist in WEB interface, only exist in command line. Below is an example
for command line.
Configuration of FXO
usr/config$ ifaddr –ip 192.168.13.68 –mask 255.255.248.0 –gate 192.168.13.254
(set IP address for 3804A)
usr/config$ sip –px 192.168.13.95 (set 3804A to register ePBX-100A-128)
usr/config$ sip –line1 888 –line2 888 –line3 888 –line4 888 (set line number)
usr/config$ security –line 1 –name 888 –pwd 888
usr/config$ security –line 2 –name 888 –pwd 888
usr/config$ security –line 3 –name 888 –pwd 888
usr/config$ security –line 4 –name 888 –pwd 888 (set ID and Password)
usr/config$ sysconf –silence 0
(disable CNG function)
You must disable CNG of 3804A due to the ePBX-100A-128 does not support CNG, otherwise there
will be some voice error occurred. Command is “
sysconf –silence 0”.
When you disable CNG, please
remember to commit and reboot your 3804A. For more information about WG3804A, please go to:
http://www.welltech.com/support/voip/SIP%20series/FXO%20series/User%20Manual%20and%20Release%
20Notes/SIPFXOA_100.pdf.