beautypg.com

Welltech ePBX-100A-128 User Manual

Page 24

background image

24

A client will normally define this value when it initially registers, so the default value you

set here will be used only if the client does not specify a timeout when it registers. If

you are registering to another SIP Trunk, this is the registration timeout that it will send

to the far end.

Codec Priority

„ Codec Priority: Codec negotiation is attempted in the order in which the Codecs

Priority is defined. Default is G729 with first priority, G711u with second priority, G711A

with third priority and GSM is fourth priority. That means the ePBX-100A-128 can only

recognize these four Codecs and it will force the Codecs with the specified priority and

forward to another subscriber. Now, ePBX-100A-128 can support G729, G711U,

G711A, GSM and G723 Pass-Thru.

PBX Setting

„ CDR Mode: Chose the mode for CDR. You can disable the CDR or send the CDR

record to a certain CDR server. You can also store the CDR records within

ePBX-100A-128.

Disable: Chose this one to Disable CDR function.

RealTime: You can install a CDR program to collect and store CDR records. The

CDR program is Welltech proprietary. For more information about such CDR

program, please contact with your contact window of Welltech.

Note:

If you choose the CDR Mode to RealTime, You should install a CDR program to

collect and store CDR records. You must also input the IP of CDR server into the

[CDR-Server IP] field. Every 5 seconds, ePBX-100A will send a CDR record to

CDR-Server by port 23519. And CDR-Server will collect such records as a CSV

file. The port of CDR server is changeable. Default is 23519.


Storage: If you do not prepare a PC as a CDR server. You can also define the

CDR Mode to Storage. ePBX-100A-128 will store the CDR records within itself.

Note:

If you chose the CDR Mode to Store, you can download the CDR file by pressing

Export button of Export CDR field. When you export CDR files, ePBX-100A-128

will clean the CDR record from it. ePBX-100A-128 can only store 500 CDR

records within itself. If you do not export the CDR file but the records is over than

500, the oldest one will be instead by newest CDR record.

„ CDR-Server IP:

If you choose the CDR Mode to RealTime, here you can input the IP

address of CDR server which you installed the Welltech CDR program.

„ CDR-Server Port: If you choose the CDR Mode to RealTime, here you can change the