background image

CHAPTER 4 • DATA PAGE

41

Note

DataView does not track the original source of the data, whether from data files or
Collector. If a sensor’s station assignment changes from one importation to another,
DataView does not recognize that the data came from two different sources. Once
data is imported and assigned to a station, records of the sources are not available.

PRN Settings

In order to facilitate the import of PRN data files into DataView, mappings must be made

between the PRN IDs and the stations that are registered in DataView. Clicking on the PRN

Settings tab will take you to the PRN Settings page (see Figure 4.9).

Figure 4.9 – PRN Settings

Each time a PRN file with new ID numbers is imported into DataView using the Import

tab, an entry is made in the PRN list. The PRN list is made up of following columns derived

from the information inside the PRN file:

˽

Station Number

˽

Id Number

˽

Classifier Address

˽

City

˽

County

˽

Location

Not all fields may have an entry, depending on the PRN file. Rows in the PRN list can be

sorted by clicking on a column header; clicking a second time will sort in the opposite

direction.

DataView will attempt to match each PRN station ID with an existing station ID from

the stations currently registered in DataView. Any PRN entry that has been automatically
matched (or manually mapped) will show a icon. Entries that do not currently have a

mapping to an existing station will show a icon. Auto-matched entries should show the