37x5 to FEP-4600 Migration and Planning Guide

707117-003

7-11

VTAM Cross Domain Resource Manager Changes

Since resources in the foreign network no longer appear to be on a foreign network, you
need to remove references to the foreign network(s) from the CDRM Major Node table.
This includes all foreign NETWORK references and GWPATH references for networks
now fronted by the FEP-4600, along with CDRMs that are located in those networks.
These will be replaced by a CDRM entry for each subarea that is defined to the FEP-
4600. (References to the foreign CDRMs and foreign networks will continue to be
referenced in the ADJSSCP table.)


CDRM Example 1:

CDRM for VTAM 03 (Before)

CDRMSA03 VBUILD

TYPE=CDRM

NETWORK

NETID=NET2

ACME1

CDRM

CDRDYN=YES,CDRSC=OPT

GWPATH GWN=GWNCP4,ADJNET=NULL,ADJNETSA=99,ADJNETEL=1



CDRM for VTAM 03 (After)

CDRMSA03 VBUILD

TYPE=CDRM

FEP4600 CDRM

CDRDYN=YES,CDRSC=OPT,SUBAREA=5


Without the NETWORK reference, the NETWORK is assumed to be NET1 (the local
network). FEP4600 is the name being given to the subarea for the FEP-4600 but can be
any valid name as long as it is also configured in the FEP-4600.


CDRM Example 3:

CDRM for VTAM 03 (Before)

CDRMSA03 VBUILD

TYPE=CDRM

NETWORK

NETID=NET2

ACME1

CDRM

CDRDYN=YES,CDRSC=OPT

GWPATH GWN=GWNCP4,ADJNET=NULL,ADJNETSA=99,ADJNETEL=1
NETWORK

NETID=NETB

BRF1

CDRM

CDRDYN=YES,CDRSC=OPT

GWPATH GWN=GWNCP4,ADJNET=NETX,ADJNETSA=38,ADJNETEL=1
NETWORK

NETID=NETQ

PDK1

CDRM

CDRDYN=YES,CDRSC=OPT

GWPATH GWN=GWNCP4,ADJNET=NETX,ADJNETSA=12,ADJNETEL=1