beautypg.com

Visara FEP-4600 Planning Guide User Manual

Page 35

background image

37x5 to FEP-4600 Migration and Planning Guide

707117-003

2-17

Example



In the example diagram:

1. A PU 2.0 platform connects to the FEP-4600 through an interface configured to

accept dynamic connections.

2. An XID exchange results in the submission of an XID of ‘01700123’ by the PU

2.0 platform.

3. The XID is linked internally by the FEP-4600 to a host connection that matches

the XID ‘01700123’. This match is assigned to Subchannel Address 00 by the
FEP-4600 configuration. Other vital information is part of this configured CU
definition such as:
 ESCON interface number

 LPAR number

 CUADD
 Link through an ESCON switch (optionally)

4. The FEP-4600 establishes communication to VTAM over Subchannel 00.
5. SNA PU 2.0 communication flows end to end.



VTAM Local Channel
Major Node PU 2.0
Definitions

FEP-4600
Host Connections

Dynamic
Interface
Definitions

PUSNA00 PU CUADDR=300
PU0LU2 LU LOCADDR=2
PU0LU3 LU LOCADDR=3
PU0LU4 LU LOCADDR=4


PUSNA01 PU CUADDR=301
PU1LU2 LU LOCADDR=2
PU1LU3 LU LOCADDR=3
PU1LU4 LU LOCADDR=4


PUSNA02 PU CUADDR=302
PU2LU2 LU LOCADDR=2
PU2LU3 LU LOCADDR=3
PU2LU4 LU LOCADDR=4


CPU LPAR

FEP-4600

Subchannel 00
IDBLK=017
IDNUM=00123

Subchannel 01
IDBLK=017
IDNUM=00456

Subchannel 02
IDBLK=017
IDNUM=00789

ESCON

XID=01700123

PU 2.0
Platform