Visara FEP-4600 Planning Guide User Manual
Page 76
Chapter 6. Support of PU 4 Connections
6-20
707117-003
Example 2:
This example is very nearly the same, except that this time both LPARs have access
directly to the FEP-4600 to get to two different destinations. Note that on the FEP-4600 it
will be necessary to use a separate CU definition to connect to each of the two LPARs.
Note that there would need to be two CHPIDs into the switch.
RESOURCE PARTITION=((PRODA,1),(PRODC,3))
CHPID PATH=(1F),TYPE=CNC,SWITCH=03,PART=(PRODC)
CHPID PATH=(27),TYPE=CNC,SWITCH=03,PART=(PRODA)
CNTLUNIT CUNUMBR=1F00,PATH=1F,UNITADD=((00,1)),UNIT=SCTC,CUADD=0,LINK=C5
IODEVICE CUNUMBR=1F00,ADDRESS=(680,1),UNIT=SCTC,UNITADD=00,PARTITION=(PRODC)
CNTLUNIT CUNUMBR=1A00,PATH=27,UNITADD=((00,1)),UNIT=SCTC,CUADD=0,LINK=C5
IODEVICE CUNUMBR=1A00,ADDRESS=(720,1),UNIT=SCTC,UNITADD=00,PARTITION=(PRODA)
Note that since the two CNTLUNIT definitions are referencing two different LPARs the
CUADD values can be defined to be the same value (in this case CUADD=0).
Once again, the definitions are shown where the two LPARs exist in Channel Subsystem
0.
RESOURCE PARTITION=(CSS(0),(PRODA,1),(PRODC,3))
CHPID PATH=(CSS(0),1F),TYPE=CNC,SWITCH=03,PART=((CSS(0),PRODC))
CHPID PATH=(CSS(0),27),TYPE=CNC,SWITCH=03,PART=((CSS(0),PRODA))
CNTLUNIT CUNUMBR=1F00,PATH=(CSS(0),1F),UNITADD=((00,1)),UNIT=SCTC,LINK=(CSS(0),C5)
IODEVICE CUNUMBR=1F00,ADDRESS=(680,1),UNIT=SCTC,UNITADD=00,PARTITION=((CSS(0),PRODC))
CNTLUNIT CUNUMBR=1A00,PATH=(CSS(0),1F),UNITADD=((00,1)),UNIT=SCTC,LINK=(CSS(0),C5)
IODEVICE CUNUMBR=1A00,ADDRESS=(720,1),UNIT=SCTC,UNITADD=00,PARTITION=((CSS(0),PRODA))
FEP-4600
PRODA
1
PRODC
3
Remote Networks
CPU
SW03
1F
C5
27