FAXBACK REQUEST FORM #2
500 TA
Page 91
request ISDN data service. You should also provide the long distance carrier with the
directory number(s) you will be using.
ISDN SERVICE PROVIDER: The following is a list of ISDN line configu-
ration requirements for the 500 TA. In addition to the basic requirements, the
optional features listed above should also be incorporated into the line setup.
ISDN Physical Line Requirements:
• 2B+D Basic Rate Interface (BRI), 2B1Q U interface (ANSI T1.601)
• NIUF Standard Line Configuration Line Set (NIIG) 11.
ISDN Line Configuration Requirements:
The 500 TA supports the following switch types and versions:
• AT&T 5ESS
5E4.2 and later, Custom or Standard (NI-1)
• Northern Telecom DMS100
BCS-29 and later,
PVC0 - PVC-1 or PVC2 (NI-1)
• Siemens EWSD 10.0 and later
NI-1
• Other NI-1 Compliant
NI-1
The following bearer capabilities are required:
• Circuit mode voice (circuit switched voice, CSV) service for speech and 3.1 kHz
audio.
• Circuit mode data (circuit switched data, CSV) for 56 kbps and 64 kbps unrestricted
data.
• Simultaneous circuit switched voice (CSV) and circuit switched data (CSD) calls.
AT&T
General:
Line Set (NIIG)
11
B1 Service
On Demand (DMD)
B1 Long Distance Access Rate
64 kbps (desired)
B2 Service
On Demand (DMD)
B2 Long Distance Access Rate
64 kbps (desired)
Data Line Class
Point-to-Point (PP) or Multi-Point (MP)
desired
Maximum
B
Channels 2
Circuit Switched Voice (CSV) Bearer Channels - Any
Number of CSV Calls
1
Circuit Switched Voice (CSD) Bearer Channels - Any
Number of CSD Calls
1
Terminal Type
A
Hold, Conference, Drop
No
Caller
ID No
ISDN Line Configuration Request Form #2
Page 2 of 3