Verilink Productivity 500 (34-00236) Product Manual User Manual
Page 21

Network Setup
500 TA
Page 21
Provider
Switch
Type
Provider
Supplied
Info
500 TA Switch Options
AT&T
Multi-Point
2 SPIDs
2 DNs
1) Set Switch Type to AT&T
2) Set Switch Version to AT&T Multi-Point
3) Set Data TEI to Auto
4) Set Data SPID and DN to provider supplied SPID
and DN
5) Set Voice TEI to Auto
6) Set Voice SPID and DN to provider supplied SPID
and DN
AT&T
Point-to-Point
1 DN
1) Set Switch Type to AT&T
2) Set Switch Version to AT&T
3) Point-to-Point
4) Set Data TEI to Auto
5) Set Data DN to provider supplied DN
6) Set Voice TEI to Disabled
Northern Telecom
DMS100
PVC IC-0
DMS100
PVC IC1
(simultaneous
voice and data)
2 SPIDs
2 DNs
1) Set Switch Type to Northern Telecom DMS100
2) Set Switch Version to PVC IC-0 or PVC IC-1
(depending on information supplied to you)
3) Set Data TEI to Auto
4) Set Data SPID and DN to provider supplied Data
SPID and DN
5) Set Voice TEI to Auto
6) Set Voice SPID and DN to provider supplied Voice
SPID and DN
Northern Telecom
DMS100
PVC IC-0
DMS100
PVC IC1
(voice or data, not
simultaneous)
1 SPID
1 DN
1) Set Switch Type to Northern Telecom DMS100
2) Set Switch Version to PVC IC-0 or PVC IC-1
(depending on information supplied to you)
3) Set Data SPID and DN to provider supplied SPID
and DN
4) Set Voice TEI to Disabled
5) Set Voice SPID and DN to provider supplied SPID
and DN
National ISDN
-----------
Same as Table 1