beautypg.com

Network protection, Indicators – Verilink C100 (880-502893-001) Product Manual User Manual

Page 90

background image

C100 and C150 Specifications

A-2

Verilink C100 and C150 T1/FT1 CSU/DSU

6/15/99

Interfaces—Electrical (DSX-1 Channel)

(C150 only) Bipolar AMI/B8ZS

Mechanical—Sync Channel

RS530, RS422, RS232; 25 Pin female V.35; 34 Pin female

Mechanical—DSX-1 Channel (C150 only)

Bipolar: 8-position RJ48C

Format, Sync channel

Binary Serial Synchronous

Format, DSX-1 channel

(C150 only) Bipolar AMI

LDM Mode

Will drive up to 6000 feet when used as
LDM (Limited Distance Modem).

Network protection

Pulse Insertion

Pulse Insertion will occur when the CI
inputs more than 15 consecutive ZEROS o
when the CI does not input at least “n”
ONES in each and every time window of 8 X
(n+1) bits (where “n” = 1 to 23).

Certification

Meets FCC Part 15 and Part 68 Complies
with AT&T Tech Pub 62411, 54016 and ANSI
T1.403-1989

Programming

Programmed by 7 DIP switch packs or
ASCII CRT

Console Port

Compatible with VT100 CRTs. RS232
interface with speed of 9600 bps with 8 data
bits, 1 stop bit and no parity. Supports dial-
in modems. Control-D used for disconnect.

Indicators

CI Chan TX DATA

Lit when CI RX DATA is spacing.

CI Chan RX DATA

Lit when CI TX DATA is spacing.

CI CCI Chan RTS

Lit when CI RTS is spacing.

CI Chan CTS

Lit when CI CTS is spacing.

CI Chan DSR

Lit when CI DSR is spacing.

CI Chan Carrier

Lit when Carrier to Channel is on.

CI Chan DTR

Lit when CI DTR is spacing.

This manual is related to the following products: