Network protection, Indicators – Verilink C100 (880-502893-001) Product Manual User Manual
Page 90
C100 and C150 Specifications
A-2
Verilink C100 and C150 T1/FT1 CSU/DSU
6/15/99
Interfaces—Electrical (DSX-1 Channel)
(C150 only) Bipolar AMI/B8ZS
Mechanical—Sync Channel
RS530, RS422, RS232; 25 Pin female V.35; 34 Pin female
Mechanical—DSX-1 Channel (C150 only)
Bipolar: 8-position RJ48C
Format, Sync channel
Binary Serial Synchronous
Format, DSX-1 channel
(C150 only) Bipolar AMI
LDM Mode
Will drive up to 6000 feet when used as
LDM (Limited Distance Modem).
Network protection
Pulse Insertion
Pulse Insertion will occur when the CI
inputs more than 15 consecutive ZEROS o
when the CI does not input at least “n”
ONES in each and every time window of 8 X
(n+1) bits (where “n” = 1 to 23).
Certification
Meets FCC Part 15 and Part 68 Complies
with AT&T Tech Pub 62411, 54016 and ANSI
T1.403-1989
Programming
Programmed by 7 DIP switch packs or
ASCII CRT
Console Port
Compatible with VT100 CRTs. RS232
interface with speed of 9600 bps with 8 data
bits, 1 stop bit and no parity. Supports dial-
in modems. Control-D used for disconnect.
Indicators
CI Chan TX DATA
Lit when CI RX DATA is spacing.
CI Chan RX DATA
Lit when CI TX DATA is spacing.
CI CCI Chan RTS
Lit when CI RTS is spacing.
CI Chan CTS
Lit when CI CTS is spacing.
CI Chan DSR
Lit when CI DSR is spacing.
CI Chan Carrier
Lit when Carrier to Channel is on.
CI Chan DTR
Lit when CI DTR is spacing.