Programming the ds-0s and dsx-1s (c100 and c150), Ds-o assignment, Ds-o assignment -15 – Verilink C100 (880-502893-001) Product Manual User Manual
Page 39: Table 3-6
Configuration Using the DIP Switches
06/17/97
C100 and C150 T1/FT1 CSU/DSU
3-15
Programming the DS-0s and DSX-1s (C100 and C150)
Switch packs 5, 6, and 7 settings are required for both the C100 and
C150.
DS-O assignment
Switch packs 5, 6 and 7 are used to determine whether a DS-0 is give
to the Synchronous Channel or the DSX-1. There are twenty-four DS-0s
in a T-1 frame and these DS-0s may be assigned to the Channel or DSX-
1 on a contiguous or non-contiguous basis.
If the switch position is Off (rocker arm down towards the front panel),
the DS-0 is not used or assigned to the DSX-1, depending on whether
the unit is a C100 or C150.
If the switch position is On, the DS-0 is assigned to the Synchronous
Channel. Even when the DSX1 interface is disabled, this selection must
be made in order to determine how many DS-0s go to the Synchronous
Channel
The programming of the DS-0s must match the DS-0 selection in the
remote unit when they are used on a point-to-point connection or they
must match the DS-0 selection on the Fractional T-1 facility provided
by the T-1 Carrier supplier.
Table 3-6
Switch pack-5: C100/C150 DS0-01 through DS0-08 and C150 DSX1-01 through DSX1-08
1
2
3
4
5
6
7
8
C100 Setting
C150 Setting
Off
-
-
-
-
-
-
-
DS0-01 not used
DSX1-1
On
-
-
-
-
-
-
-
DS0-01 to Channel
Off
-
-
-
-
-
DS0-02 not used
DSX1-2
On
-
-
-
-
-
DS0-02 to Channel
-
Off
-
-
-
-
DS0-03 not used
DSX1-3
-
On
-
-
-
-
DS0-03 to Channel
-
-
Off
-
-
-
DS0-04 not used
DSX1-4
-
-
On
-
-
-
DS0-04 to Channel
-
-
-
Off
-
-
DS0-05 not used
DSX1-5
-
-
-
On
-
-
DS0-05 to Channel
-
-
-
-
Off
-
DS0-06 not used
DSX1-6
-
-
-
-
On
-
DS0-06 to Channel
-
-
-
-
-
Off
DS0-07 not used
DSX1-7
-
-
-
-
-
On
DS0-07 to Channel
-
-
-
-
-
-
Off
DS0-08 not used
DSX1-8
-
-
-
-
-
-
On
DS0-08 to Channel
Off
Off
Off
Off
Off
Off
Off
Off
Factory default setting