User Guide - EZMesh Full Duplex Mesh Network Access Point

EXAMPLE: (IP address and Gateway should under same domain.)

Mesh IP Address: 192.168.0.120, and Gateway IP: 192.168.0.1

Http Port

The default Http Port for MeshAP is 80. Http Port could be set to any port number based

on the network administrator’s requirement.

To reassign a number Http Port enter the desire port number to Http Port field. And Click

Save Setting and Apply

Https Port

The default Https Port for MeshAP is 443. Http Port could be set to any port number based

on the network administrator’s requirement.

To reassign a number Http Port enter the desire port number to Https Port field. And Click

Save Setting and Apply

Weight

Weight number (1 – 10) help identify the level of connection desire for the nodes (Stations)

to connect to particular Mesh Manager unit on the Mesh. Setting a Mesh Manager’s Weight

to “10” may force all nodes on the mesh network to associate with this Mesh Manager than

other Mesh Manager on the mesh. Whereas Setting Mesh Manager to “1” may force this

Mesh Manager low chance for Nodes to associate to compare with other high Weight

number Mesh Manager on the mesh.

Note: Total Bandwidth score is based on Hop Count, Signal Quality, and Mesh Manager

Weight. This guideline affects the routing decision of each node on the mesh to decide

which Mesh Manager to associate

To set Mesh Manager weight, Enter number (1-10) in the “Weight of this Mesh Network”

field and Click Save Setting and Apply