Teletronics EZMesh User Manual
Page 15
User Guide - EZMesh Full Duplex Mesh Network Access Point
1. You can attach any outdoor EZMesh access point to any light pole
2. Mount the access point to the pole within 3ft. of the outdoor lighting control.
3. Connect a 10-AWG or larger ground wire to one of the EZMesh access point screw.
Make sure it is connected to a reliable earth ground, such as a grounded pole or a
grounding rod.
Warning: This equipment must be externally grounded using a customer supplied ground
wire before power is applied. Contact an electrician if you are uncertain that suitable
grounding is available.
Notes: When powering the product with AC power the power plug should be installed
where it can be conveniently accessed to de-energize power from the unit. Power should
not be removed by disconnecting the AC power connector itself and where it is not
subjected to water or outdoor elements.
Warning: Be careful when connecting the street light adapter to the pole. You may fall or
electrocute yourself
4. Disconnect the lightning control from its fixture.
5. Make sure that the voltage available is between 100 and 240 VAC 50/60Hz.
6. Turn off power to the fixture at the designated circuits
7. Connect the adapter to the access point AC power connector.
8. Make sure the antennas are connected before the MeshAP is connected to electrical
power. Failure to do so may result in permanent hardware damage to the MeshAP unit.
9. Plug the street light adapter into the outdoor control fixture
10. Plug the lighting control into the street light adapter
Note: Use your hands to tighten the cable until the connector locks.
11. Use either a level or the attached circular level to align the MeshAPs external antennas.
Loosely assemble the rest of the pole mount kit around the pole
Note: Each pole clamp is equipped with the bolts of the appropriate length. If a different
length is required, purchase 3/16-16 bolts of the correct length for your installation.
Note: Leave the screws somewhat loose so you can adjust the access point’s orientation.
TELETRONICS INTERNATIONAL, INC.
- 11 -