beautypg.com

2 – names and functions of parts, Front panel – Teac CG-2000 User Manual

Page 8

background image

8

TASCAM CG-2000

2 – Names and functions of parts

Front panel

1

LOCK indicator

This shows if the output clock and reference clock are

locked.

Lit: The output clock phase is synchronized with the

reference clock phase.
Blinking: The output clock phase is not synchronized

with the reference clock phase.
Examples:
o When the reference clock is being chased when it is

switched by the reference redundancy function

o

When the backup reference clock is operating

2

SELECT reference clock indicators

This shows the selected reference clock and its operation

status.

Lit: Now selected and used for reference (including

secondary)
Blinking: Selected for reference, but not being used
Unlit: Reference clock that is neither selected nor being

used

3

SIGNAL indicators

This shows the input status of each reference clock signal.

Lit: Clock is being input and is locked
Blinking: Clock is being input but is not locked
Unlit: Clock is not being input

NOTE

The INTERNAL indicator will blink to show the temperature

of the constant temperature control tank is unstable for

about three minutes after the OCXO (oven-controlled

crystal oscillator) is started as well as if the temperature of

the constant temperature control tank is irregular.

4

Display

This shows various information.

5

INFO indicator/button

Lit blue: Indicates ordinary operation. Press the INFO

button to show the status of the unit on the display.
Lit red: Indicates trouble. Press the INFO button to show

information about the error on the display. Press again

to show the status of the unit.

6

HOME/DISPLAY button

Press when a menu screen is open to return to the Home

Screen.
While pressing and holding this button, turn the MULTI JOG

dial to adjust the brightness of the display and the various

indicators.

7

MULTI JOG dial

This dial also functions as a button.
Dial functions

In menu mode, use to select menu items and setting

values.
While pressing and holding the HOME/DISPLAY button,

turn the MULTI JOG dial to adjust the brightness of the

display and the various indicators.
When the

INFORMATION

screen or the

ERROR

INFORMATION

screen is open, turn the MULTI JOG

dial to scroll through various information.

Button function

Use as the ENTER button to confirm selections and

settings.

8

PRESET indicators/buttons (1–4)

Use these buttons to save and recall preset settings. (See

“Recalling presets” on page 21.)
Ordinarily, the indicator for the button of the most recently

recalled preset is lit

9

SET button

Press to save the current settings to one of the PRESET

buttons. (See “Saving the current settings as a preset” on

page 21.)

0

PANEL LOCK switch

Slide this switch to the right to disable all operation from the

front panel. To enable operation from the front panel, slide

this switch to the left.

NOTE

The INFO and HOME buttons, as well as the

INFOR-

MATION

and

ERROR

Information screens can still be used.

q

REFERENCE REDUNDANT indicator

This shows the operation of the reference redundancy

function.

Lit: The reference redundancy function is on and both

the primary and secondary reference clocks are locked.
Blinking: The reference redundancy function is on and

either the primary or secondary reference clock is not

locked, or the reference clock is set to INTERNAL.
Unlit: The reference redundancy function is off.

w

POWER REDUNDANT indicator

This shows the operation of the power redundancy function.

Lit: The power redundancy function is on and both

circuits are operating.
Blinking: The power redundancy function is on, but only

one circuit is operating.
Unlit: The power redundancy function is off.

e

MENU button

When the Home Screen is open, press this button to open

the menu screen.