TASCAM CG-2000

9 – Other functions

Alarm output

This unit has a function that allows it to output an alarm through

a dedicated connector when trouble occurs. To use this function,

just connect the

ALARM OUTPUTS

connectors as required.

ALARM OUTPUTS connectors

Pin

Details

1

+5V

2

Outputs when there is an unchecked error log

3

GND

4

+5V

5

Outputs while an error is occurring.

6

GND

Power redundancy function

This unit has two power supply circuits, and supports redun-

dancy to prevent problems related to the power supply.
By default, the power redundancy function is off. If you want

to use it, follow the procedures below to turn this function on

and connect two different power supplies to the two power

connectors.
If the power redundancy function is on when only one of

the power circuits is connected, the unit will determine that

one power supply has been interrupted and the POWER

REDUNDANT indicator on its front will blink. In this case, turn

the power redundancy function off.

Setting the power redundancy function

You can turn the power redundancy function on or off.
Make this setting from the

UTILITY 1

page.

1. Press the MENU button repeatedly to open the

UTILITY

1

menu page, and turn the MULTI JOG dial to select the

POWER RED.

item.

2. Press the MULTI JOG dial to open the

POWER

REDUNDANT

screen.

3. Turn the MULTI JOG dial to turn the power redundancy

function on or off.
Options: OFF (default), ON

4. Press the MULTI JOG dial to confirm the selection and return

to the menu.

NOTE

Press the EXIT/CANCEL button while making a setting to

cancel the change and return to the menu screen.

Setting the termination for reference

input connectors

Set the termination for each input connector according to the

wiring.
Make these settings on the

TERMINATION

page.

1. Press the MENU button repeatedly to open the

TERMI-

NATION

menu page, and turn the MULTI JOG dial to select

the input connector for which you want to set the termi-

nation.

VIDEO A selected

2. Press the MULTI JOG dial to open the

TERMINATION

XXX

screen (“ XXX” is the name of the input connector).

TERMINATION VIDEO A

screen open

3. Turn the MULTI JOG dial to set the termination for the input

connector.
Options

Video clock input connector: 75ohm (default), OPEN
Word clock input connector: 75ohm (default), 50ohm,

OPEN
GPS signal input connector: 50ohm (default), OPEN

4. Press the MULTI JOG dial to confirm the selection and return

to the menu.