9 – Other functions

Setting the levels of the word clock

outputs

You can change the output levels of the word clock outputs.

Change these levels on the

WORD OUT LEVEL

page.

1. Press the MENU button repeatedly to open the

WORD

OUT LEVEL

menu page, and turn the MULTI JOG dial to

select the word clock output connectors for which you want

to set the level.

1/2 selected

2. Press the MULTI JOG dial to open the

WORD OUT

LEVEL 1/2

screen.

WORD OUT LEVEL 1/2

screen open

3. Turn the MULTI JOG dial to set the output level of the word

clock output connectors.
Options: 1.0V, 1.5V, 2.0V, 2.5V (default), 3.0V, 3.5V

4. Press the MULTI JOG dial to confirm the selection and return

to the menu.

Restoring factory default settings

You can restore the various settings saved in this unit’s backup

memory to their factory defaults.
Do this from the

UTILITY 1

page.

See “Default setting values list” on page 28 for the settings

when the unit is shipped new from the factory.

NOTE

The

STARTUP

item setting cannot be restored to the

factory default.

1. Press the MENU button repeatedly to open the

UTILITY

1

menu page, and turn the MULTI JOG dial to select the

FACTORY PRESET

item.

2. Press the MULTI JOG dial to open the

FACTORY

PRESET

pop-up.

3. Press the MULTI JOG dial to execute, or press the EXIT/

CANCEL button to cancel.

Setting the startup preset

You can set the preset used at startup when this unit is turned

on. Make this setting on the

UTILITY 1

page.

1. Press the MENU button to open the

UTILITY 1

menu

page, and turn the MULTI JOG dial to select the

STARTUP

item.

2. Press the MULTI JOG dial to open the

STARTUP MODE

screen.

3. Turn the MULTI JOG dial to set the preset used at startup.

Option

Function

LAST (default)

Startup with last used settings

PRESET 1

Startup with the corresponding preset

settings

PRESET 2
PRESET 3
PRESET 4
FACTORY

Startup with factory default settings

NOTE

The

STARTUP

item setting cannot be restored to the

factory default.

4. Press the MULTI JOG dial to confirm the selection and return

to the menu.

Calibrating the internal oscillator

The importance of calibration

This unit has an OCXO (oven-controlled crystal oscillator) that

provides 0.01ppm high-precision frequency output. However,

every clock generator, including this one, can normally be

expected to change over time.
In order to enable continued use with high-performance, this

unit has a function for calibrating the internal oscillator.
If you connect and input a 10MHz signal generated from

a GPS signal or a PPS signal, for example, to the dedicated

CALIBRATION INPUT

connector, the unit will recognize it

automatically and calibrate the internal clock.

Checking the unit firmware version

Follow these procedures to check this unit’s firmware version.
Do this before updating the firmware, for example.
1. Press the MENU button repeatedly to open the

UTILITY

2

menu page, and turn the MULTI JOG dial to select the

VERSION

item.