5 – Reference redundancy function

AUTO SW (automatic switching) mode

In this mode, after the unit has switched to the secondary

reference clock, it will not switch back to the primary reference

clock automatically when the primary reference clock recovers.

If the secondary reference clock is lost, it will switch back to the

primary reference clock (if it is available).
After the unit has switched to the backup reference clock, it will

switch immediately to the primary reference clock or secondary

reference clock when it recovers.

Step

Clock status

Reference clock

status

Note

Primary

reference

clock

Secondary

reference

clock

1

Primary

reference clock

2

Secondary

reference clock

3

Secondary

reference clock

4

Primary

reference clock

2

5

Backup reference

clock

6

Secondary

reference clock

: ENABLED

–: DISABLED
2: The unit switches when the reference clock in use is lost.

ONE WAY mode

In this mode, the unit does not switch automatically when a

higher priority reference clock recovers. Restarting the reference

clock (see below) is necessary to return to the higher priority

clock.

Step

Clock status

Reference clock

status

Note

Primary

reference

clock

Secondary

reference

clock

1

Primary

reference clock

2

Secondary

reference clock

3

Secondary

reference clock

4

Backup reference

clock

3

5

Backup reference

clock

6

Backup reference

clock

: ENABLED

–: DISABLED
3: Even if the reference clock is lost, the unit will not switch to a

higher priority reference clock.

Setting the sequence mode

Follow these procedures to set the sequence mode used for

switching with the reference redundancy function.
1. Press the MENU button to open the

REFERENCE

menu

page, and turn the MULTI JOG dial to select the

RED.

SEQ

. item.

2. Press the MULTI JOG dial to open the

RED. SEQUENCE

screen.

3. Turn the MULTI JOG dial to set the sequence mode for the

reference redundancy function.
Options: PREF. PRI. (default), AUTO SW, ONE WAY

4. Press the MULTI JOG dial to confirm the selection and return

to the menu.

Restarting reference clock switching

In one-way mode, after the unit switches to the backup

reference clock, “restarting” is necessary to switch back to

the primary reference clock. In addition, when using one of

the automatic switching modes, you can also use the restart

function to force the unit to switch back to the primary

reference clock.
Make this setting on the

REFERENCE

page.

1. Press the MENU button to open the

REFERENCE

menu

page, and turn the MULTI JOG dial to select the

RED.

RESTART

item.

2. Press the MULTI JOG dial to open the

RED. RESTART

pop-up.

3. Press the MULTI JOG dial to restart the reference redun-

dancy function using the primary reference clock, and return

to the menu screen.