6 Set the following items.

LEVEL

Specify the sync level.

You can set this in a range of -72 dB – -24 dB (6 dB

steps). (The default setting is -54 dB).
DELAY

Specify the time (in steps of one frame) from when a

signal exceeding the sync level is detected until record-

ing will begin (one frame is 1/75th of a second).

You can set this in a range of -75 frames – +75 frames

(the default setting is 0). If you specify a negative value,

the corresponding length of audio prior to triggering

will also be captured.

NOTE

When this range is converted to seconds, it is equiva-
lent to -1.00 seconds – +1.00 seconds.

STOP TIME

When the signal has remained below the sync level for

the length of time you specify here, recording will stop

and the SS-CDR1 will enter record-pause mode.
You can specify this in a range of 5 ˗ 30 seconds (one-

second steps) or INF (∞). (The default setting is 5

seconds. Choose

INF

if you do not want recording to

stop automatically.)