Super Systems SuperDATA User Manual
Page 29

Super Systems Inc
Page 29 of 172
Super Data Operations Manual
Note: Items enclosed in brackets [ ] are optional but may be required for certain instrument types.
Item
Definition
C
Optional. Applies to ALL instruments. Specifies the Connection Identifier (1-8
for serial connections and 9 for Ethernet). The protocol for the connection
must match the protocol for the instrument. If not included, defaults to
Connection 1.
LLL
Required. Applies to ALL instruments.
The logical channel number assigned (1-
128).
PPP
Required. Applies to ALL instruments. (see MMI Instrument Physical
Addresses )
ID
Required. Applies to ALL instruments.
The instrument ID: 10PRO or
BARBER-COLEMAN-560
NOLOG
Optional. Applies to ALL instruments.
Do not log data from this channel.
Include this when communications are required for real-time data but are not
required for historical data logging. If this is not included, the channel will be
data logged at one minute intervals.
ABC
Optional. Applies to ALL instruments.
Alarm Block Configuration .
Caution:
any specified channel can use either ALM or ABC but not both.
Allows a custom
Alarm Block Bitmap (one word) to be setup for any instrument but generally
used only for non-programmable instruments that are not capable of
maintaining alarm bitmaps. See the section on Custom Alarm Block
Configuration.
TAG
Required. Applies to ALL instruments.
Instrument name. Limited to 12
Characters with no spaces.
MMI V3 and V3.5 Instruments
[C]CH#LLL(PPP ) = "ID,[PROG],[BC CONT ],[AEVT ],[EVT ],[NOLOG],[ABC] " = "tag "
Examples:
2CH#22(2)=" UCARB-V3.0,PROG(3),BC_CONT,EVT(4)"="FCE_2"
2CH#23(3)=" UNIPRO,PROG(3),EVT(4)"="TEMPER_1"
Note: Items enclosed in brackets [ ] are optional but may be required for certain instrument types.
Item
Definition
C
Optional. Applies to ALL instruments. Specifies the Connection Identifier (1-
8 for serial connections and 9 for Ethernet). The protocol for the connection
must match the protocol for the instrument. If not included, defaults to
Connection 1.
LLL
Required. Applies to ALL instruments.
The logical channel number assigned
(1-128).
PPP
Required. Applies to ALL instruments.
(see MMI Instrument Physical
Addresses )
ID
Required. Applies to ALL instruments.
The instrument ID: MCARB-V3.0,
UCARB-V3.0,
UCARB-V3.5,
MCARB-IR,
MCARB-IR-V3.5,
UNIPRO,
UNIPRO-V3.5
PROG
Optional. Always set this to PROG(3) for V3 and V3.5 Instruments..
BC CONT
Optional. Used to indicate if a V3.x Carb instrument has an attached BC560
or 10Pro controller for temperature.
AEVT
Optional. Used to indicate if a V3.x instrument has attached analog events
on the events port. Indicate the number of analog modules: e.g. AEVT(4).
EVT
Optional. Used to indicate if a V3.x instrument has attached digital events
on the events port. Indicate the number of digital modules: e.g. EVT(4).