7.12 Setup VCO 2
The user sets up the VCO2 frequency by giving it a frequency to output (given the
frequency is in the VCO’s range).
7.13 Setup Clock A
The user sets up the required clock frequency (given it is in the correct range) and clock
synthesizers applies this frequency to the clock A output.
7.14 Setup Clock B
The user sets up the required clock frequency (given it is in the correct range) and clock
synthesizers applies this frequency to the clock B output.
7.15 Multiplex Trigger A CONT or PULSE
User selects if trigger line A is a continuous trigger or a single pulse. 0 for continuous or
1 for single pulse.
7.16 Multiplex Trigger B CONT or PULSE
User selects if trigger line B is a continuous trigger or a single pulse. 0 for continuous or
1 for single pulse.
7.17 Setup Pulse on Trigger A
User sets up the pulse on trigger line A (by giving the high time) and generates it. Line
must be set for pulse (option 15).
7.18 Setup Pulse on Trigger B
User sets up the pulse on trigger line B (by giving the high time) and generates it. Line
must be set for pulse (option 16).