Configuration guide, Sound configuration 2 – SoundTraxx SurroundTraxx User Manual
Page 42

SurroundTraxx User’s Guide
Configuration Guide Page 2:14
SurroundTraxx User’s Guide
Configuration Guide Page 2:15
You can also set a variable wheel slip rate that causes the two sets of
exhaust chuffs to go in and out of sync with each other as if one set of
drivers were continuously 'slipping'. It is also useful for generating a
double-header sound effect.
Use the table to select between a steam engine type, slip rate, and
airpump type. Select the value from the table.
Sound Configuration 1 - Steam
Exhaust Mode and Airpump Selection
Exhaust Mode
Wheel Slip Rate
Airpump
Sound Channel Value
Coventional Rod Engine
None
Single Airpump
0
Coventional Rod Engine
None
Dual Airpump
1
Articulated Engine
None
Single Airpump
64
Articulated Engine
None
Dual Airpump
65
Articulated Engine
Slow
Single Airpump
80
Articulated Engine
Slow
Dual Airpump
81
Articulated Engine
Medium
Single Airpump
96
Articulated Engine
Medium
Dual Airpump
97
Articulated Engine
Fast
Single Airpump
112
Articulated Engine
Fast
Dual Airpump
113
Diesel
If you have a diesel locomotive SND1 will allow you to have the diesel air
compressor and cooling fans either turn on and off with a function key,
or turn on automatically. This becomes useful if your cab either doesn’t
support fourteen functions, or if you would prefer to use manual notching
and need to have F9 and F10 free for RPM+ and RPM-.
Sound Channel 1 - Diesel
Air Compressor and Cooling Fan Values
Air Compressor
Cooling Fan
Value
Manual
Manual
0
Automatic
Manual
1
Manual
Automatic
2
Automatic
Automatic
3
Sound Configuration 2
Sound Configuration 2 (SND2) allows you to enable the Quiet Mode
Timeout for the model. When Sound Configuration 2 is set to zero,
Configuration Guide