REMKO GPM User Manual
Page 27

27
Type C13 horizontal / coaxial
L1 + L2 maximum duct length
without endpieces
Ø 80
Ø 100
Model
Metres
GPM15
10 + 10
GPM25
10 + 10
GPM35
10 + 10
GPM55
4.5 + 4.5
GPM 75
4 + 4
Type C33 vertical / coaxial
L1 + L2 maximum duct length
without endpieces
Ø 80
Ø 100
Model
Metres
GPM15
11 + 11
GPM25
11 + 11
GPM35
11 + 11
GPM55
4.5 + 4.5
GPM 75
4 + 4
Gas fireplace type C
Room-air-independent combustion 
system.
The combustion cycle is compact 
compared to the environment in 
which it is installed.
The combustion air is fed from 
outside.
The ductwork runs horizontally 
through the outside wall or 
vertically through the roof.
L1
L2
Installation
height
Schematic
side view
2.5 - 3.5 m
L1
L2
Installation height
2.5 - 3.5 m
Schematic
side view
L1
L2
Installation height
2.5 - 3.5 m
Schematic
front view
In this version the position of 
the connections to the unit 
must be changed, meaning 
they must be repositioned 
from behind to above. 
This
variant is executed at the
factory and must be indicated
when ordering.
NOTE
NOTE
The installation of the exhaust 
gas routeing through the 
outside wall must correspond 
to the regulations of DVGW - 
TRGI and TRF as a basic rule 
and must be approved by the 
responsible district master 
sweep.
TYPE C33
Room-air-independent combustion 
system.
Exhaust/ and combustion air are 
led through an LAS endpiece 
through the roof.
TYPE C13
Room-air-independent combustion 
system.
Exhaust/ and combustion air are 
led through an LAS endpiece 
through the outside wall.
We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process.