beautypg.com

REMKO GPM User Manual

Page 17

background image

17

Programming of the HTG
programming timer.

With the key KM and then button
K4 (>>) you arrive at page 2 of the
menu.
With the key K1 (PROG) the
programming menu (PROG) is
selected.
After selection of this menu, one
of the following options can be
selected:
DAY

REG

COP PRE

K1

K2

K3

K4

The creation of a programme is
possible through two different
procedures:
- by creation of a new programme

with the keys DAY, REG and COP

- with key PRE and selection of a

pre-set programme.

With a power failure of more than
5 hours the set programmes are
not lost. Upon reconnection of the
power supply the current day, time
and operation mode AUTO must
be adjusted.
nicians.

New programme

With key K1 (DAY) the sequential
day for which the programming
should be done is selected; with
the keys K+ and K- the time that
the fan-assisted heater should be
switched on is adjusted.
With key K2 (REG), access to the
menu for adjustment of the
temperature takes place, which
should be programmed for a
specific length of time.
After selection of this menu, one
of the following options can be
selected:

T1

T2

T3

K1

K2

K3

K4

— the adjusted temperature

remains unchanged

T1 adjusts the respective room

temperature value

T2 adjusts the respective room

temperature value

T3 adjusts the respective room

temperature value

With key K1 (—), K2 (T1), K3 (T2)
or K4 (T3) the temperature that
should be programmed is selected;
after completed selection, the
menu of the HTG programming
mode appears on the display
again.
With the keys K+ and K- the times
for switching on and off with the
respective temperatures are now
adjusted for the selected day.
The four different parameters (-,
T1, T2 and T3) are shown during
the programming as follows:

-

Dash below flashes

T1

two balls flash alternately

T2

one ball below flashes

T3

two balls flash
simultaneously

The flashing area, which is based
on the selected temperature,
shows the position in regard to the
time that the programming was
carried out; hours and minutes are
shown on the display.
You normally only use two
temperatures with fan-
assisted heaters: one switch-on
temperature (T2, T3) and one
switch-off temperature (T1 and
T2).

After completion of the
programming of the day, the unit
either automatically returns to the
previous menu at the end of the
time available for the selection of
parameters or returns manually
by actuation of one of the keys
enabled for this (K1, K2, K3 or K4).

With key K3 (COP) the
programming of the currently
adjusted day is copied for the
following day. Select the day to
be copied with the menu (e.g.
MO - Monday), press the key
COP and then the key DAY in
order to copy the programme
for the following day, with our
example TU (Tuesday). In order
to also copy TU (Tuesday) for WE
(Wednesday), press COP and then
DAY. Of course the copied day can
be changed with the procedure
described above.

Pre-set programmes

With key K4 (PRE), you access
the menu for the selection of the
operating programme pre-set by
the HTG programming timer.
The electronic temperature
regulation provides the
opportunity to select between 5
different programmes.

After selection of this menu, one
of the following options
can be selected:

- OK or

- CANCEL

With the keys K+ or K-, a pre-set
operating programme of the HTG
programming timer is selected.
The programmes are numbered
from 1 to 5.