Remko gpm – REMKO GPM User Manual
Page 18

18
REMKO GPM
Frost protection
This function always remains active
when switching off through the
operating unit.
The fan-assisted heater switches
on if the room temperature falls
below the pre-adjusted frost
protection temperature of + 5 °C,
which cannot be changed.
If the frost protection function
should be removed, you must
contact the customer service
location.
Power reserve
The electronic temperature
regulation is supplied with power
directly from the fan-assisted
heater. It has a power reserve that
prevents the loss of programming
with power failures lasting longer
than five hours.
If the reserve is consumed, the
display no longer functions.
With renewed power supply it
resumes operation.
Temperature display
During normal operation the
temperature shown on the
display corresponds to the room
temperature measured by the
electronic temperature regulation.
For display of the set room
temperature, press key K+ or K-.
Room correction
This function is described in
the chapter for the user; it can
be switched on through the
electronic temperature regulation
by adjusting the TSP values, which
regulate this function.
For activation or deactivation of
the room correction, press and
hold key KM for approximately
8-10 seconds until the following
appears on the display:
INFO REG
ERR
>>
K1
K2
K3
K4
Press K4 (>>) and change to
the following page, where the
following appears:
LANG PAR
PARK >>
K1
K2
K3
K4
Press K3 (PARK) in order to arrive
at the TSP parameters.
The display shows:
<<
PARAM K 1
>>
K1
K2
K3
K4
The TSP values are shown on the
display by PARAM K.
Enter values according to the
following table:
PARAM
K
TSP Standard Range
11
C1
1
0-1
17
A12
1
0-1
18
A16
20
1-99
19
A24
1
1-10
After approx. 20 seconds
the electronic temperature
regulation automatically
returns to the starting display
and normal operation.
NOTE
With key K1 (OK) the choice you
have made is confirmed; then the
display shows the menu of the
HTG programming mode again.
With the key K2 (CANCEL)
you can leave the HTG - PRE
programming mode menu,
without making any selections;
the display then shows the HTG
programming mode menu again.
Programming the values T1, T2
and T3
With the keys KM, K4, >> and K2
(REG), you access the menu for
programming the desired room
temperature.
After successful selection of the
menu, the following information
appears on the display:
<<
■Room temperature T1 >>
K1
K2
K3
K4
The value of T1 appears on the
display; with the keys K+ and K-
this value can be changed.
Press K4 to access T2 and T3.
When you continue pressing K4,
other messages appear that have
no influence on the operation of
the fan-assisted heater.
When programming the
temperatures, ensure that T1 is
lower than T2 and T2 is lower than
T3.
For the values T1, T2 and T3 the
programming range lies between
+7°C and +35°C.