REMKO ML 262 DC Arctic User Manual
Page 9

▲/▼
Buttons
Cooling mode
Automatic mode
MODE Button
Use the MODE button to select between individual operating modes.
5 modes are available:
Using the button, the target temperature can be adjusted up or down by
1°C. The temperature range lies between 17°C and 30°C
1. Automatic
cooling or heating operation
2. Cooling
predominant operating mode for summer
3. Dehumidifying operating mode for summer or winter
4. Heating
predominant operating mode in winter
5. Circulation
air circulation only
MODE
MODE
MODE
Automatic
Cooling
Dehumidifying
Heating
Air circulation
In automatic mode, the controller autonomously selects between heat-
ing and cooling operation when the unit is first switched on. The control
range lies between 22 °C and 26 °C. This can be increased or decreased
with the
▲/▼ buttons. Fan speed is selected automatically.
AUTOMATIC MODE
AUTOMATIC
MODE
In cooling mode, the air in the room is cooled down to the set target
temperature. The desired room temperature is set with the
▲/▼ buttons
in 1 °C increments. If the room temperature is 0.5 °C above the selected
nominal temperature, then the interior unit starts to cool down the air
in the room. If the temperature falls to approx. 1 °C below the set room
temperature, the controller will switch off the cooling function. To protect
the compressor, the controller will not switch off the cooling again until
after a waiting period of 3 minutes.
COOLING mode
COOLING
OPERATION
MODE
▼
▲
▼
▲
9