beautypg.com

REMKO ML 262 DC Arctic User Manual

Page 13

background image

Cleaning the condensation
pump (accessories)

An optional integrated or separate
condensation pump may be
included with the indoor unit,
which pumps out any accumulated
condensation into higher
positioned drains.
Observe the care and maintenance
instructions given in the separate
operating instruction manual.

Type of task

Checks/Maintenance/Inspections

Commissioning

Monthly

Six-monthly

Yearly

General

Measure voltage and current

Check function of compressor/fans

Check fan function

Dirt on condenser/vaporiser

Check refrigerant fill quantity

Check condensation drain

Test insulation

Check moving parts

Sealing test for refrigerant circuit

1)

Cleaning the housing of the
indoor unit

1. Disconnect the supply voltage

to the equipment.

2. Open and fold the air inlet

guard on the front side
upwards.

3. Clean the guard and cover

using a soft, damp cloth.

4. Switch the supply voltage back on.

Air filter for indoor unit

Clean the air filter at intervals of

no more than 2 weeks. Reduce this

interval in case of heavily soiled air.

Cleaning the filter
of the indoor unit

1. Disconnect the supply voltage

to the equipment.

2. Open the front side of the

device by folding the guard
upwards and allowing it to
engage (figure 1).

3. Raise the filter and pull it out

pulling downwards.

4. Clean the filter with a standard

vacuum cleaner. Turn the dirty
side upward (figure 2).

5. Dirt can also be removed

by carefully cleaning with
lukewarm water and mild
cleaning agents. Turn the dirty
side downwards(figure 3).

2 Cleaning using a vacuum cleaner

3 Cleaning with lukewarm water

6. If water is used, let the filter dry

out before replacing it in the
unit.

7. Carefully insert the filter. Make

sure it is seated correctly.

8. Close the front side as

described above in reverse
order.

9. Switch the supply voltage back

on.

10. Switch the unit on again.

1 Fold the guard upwards

1) see note