Equipment description

The equipment is shipped in
in sturdy transport packaging.
Immediately check the equipment
on delivery and make note of
any damage or missing parts
on the delivery note and inform
the forwarding agent and your
contractual partner.
No warranty can be assumed for
later claims.

Transport and
Packaging

Refrigerant circuit diagram for the indoor unit

Vaporiser fan

Connection to

suction pipe

Connection to injection line

Vaporiser

The connection between the indoor unit and the outdoor component is
made by way of the refrigerant lines.

Outdoor

component

System configuration

Injection line

Indoor unit

Indoor area

Outdoor area

Stop valve

Condenser fan

Condensation line

Suction line

Condensation line

Control line

Mains cable

M

M

Refrigerant circuit diagram for the outdoor component

Condenser fan

Connection valve

Suction line

Connection valve

Injection line

Compressor

Capillary tube throttle element

Filter dryer

Condenser

Reverse flow valve

Connection

Manometer

The ML 262-522DC room air

conditioning units have a REMKO

ML...DC AT outdoor component as

well as an ML...DC IT indoor unit.
When in cooling mode, the

outdoor component serves to

release the heat extracted by the

indoor unit from the room being

cooled. When in heating mode,

the heat absorbed by the outdoor

component can be released by

the indoor unit into the room

being heated.

In both operating

modes, the performance of the

compressor adjusts itself precisely

to the demand, thereby regulating

the target temperature with minimal

temperature fluctuations. This

"inverter-technology" results in

energy savings over conventional

split systems and also reduces noise

emissions to a particularly low level.

The outdoor component can

be installed outdoors or indoors

providing that certain requirements

are met. The indoor unit is designed

to be mounted high up on indoor

walls. Operation takes place using

an infrared remote control.
The outdoor component consists of

a refrigerant circuit with compressor,

fin condenser, condenser fan,

reverse flow valve and throttle

element. The outdoor component is

controlled via the regulation of the

indoor unit.
The indoor unit consists of a fin

vaporiser, vaporiser fan, regulation

system and condensation pan.
Floor consoles, wall consoles,

refrigerant pipes and condensation

pumps are available as accessories.

5