Remko ml...dc - arctic, Decommissioning, Care and maintenance – REMKO ML 262 DC Arctic User Manual

Page 12

background image

There are individually adjustable
fins for adjusting the horizontal air
distribution on the air discharge
side.

Manual air distribution

Moving, internal parts, e.g.
fans, have the potential to
cause injury during operation!
Only make adjustments after
swing operation has been
switched off.

ATTENTION

Shift lever left

Manual air distribution

Shift lever right

Decommissioning

Temporary
Decommissioning
1. Allow the indoor unit to run for

2 to 3 hours in air circulation
mode or in cooling mode at the
maximum temperature setting
in order to remove any residual
moisture from the unit.

2. Shut down the unit using the

remote control.

3. Switch off the voltage supply to

the unit.

4. Cover the unit as far as possible

with plastic foil in order to
protect it from the influences of
weather.

Care and maintenance

Regular care and maintenance
serves to ensure trouble-free
operation and long service life of
the unit.

Care

Ensure the indoor unit and
outdoor component are
protected against dirt, mould
and other deposits.

Clean the equipment using
a damp cloth. Do not use any
caustic, abrasive or solvent-
based cleaning products.
Do not use a jet of water.

Clean the fins on the indoor
unit and outdoor component
prior to long shutdown periods.

Prior to performing any work,
ensure the equipment is
disconnected from the voltage
supply and secured to prevent
accidental switch-on!

ATTENTION

Permanent
Shutdown

Ensure that equipment and
components are disposed of in
accordance with local regulations,
e.g. through authorised disposal
and recycling specialists or at
collection points.

REMKO GmbH & Co. KG or your
contractual partner will be pleased
to provide a list of specialist
companies near you.

Maintenance

We recommend
concluding a maintenance
contract with annual service
from an appropriate specialty
company.

This ensures the operational
reliability of your system!

TIP

Statutory regulations require
an annual leak test for the
refrigerant circuit in relation to
the refrigerant filling capacity.
Inspection and documentation
is to be carried out by special-
ty technicians.

NOTE

REMKO ML...DC - ARCTIC

12