Networked single loop system with minilink pd only, Component & system wiring 13, Gn d ain2 ain1 +5v tb2 – Orion System VCM Component User Manual
Page 13: Cx14 network driver rn3, Philips

Component & System Wiring
13
EPROM
U3
U5
RAM
CX
2
1
U2
R1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILIPS
D1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D4
GN
D
24VA
C
TB1
D5
C1
1
U12
LED
2
POWER
V1
R25
R26
C7
CX
15
CX13
PROC.
DRIVER
LOOP
DRIVER
LOCAL
LOOP
GN
D
AIN2
AIN1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN1
0-10V
4-20mA
THERM
TB3
U15
LD5
LD6
U13
C8
LED
1
RV
1
R4
VREF
CX2
U1
1
YS101900PMINILINK
POLLING
DEVICE
REV
.
1
OFF
1
2
4
8
16
32
CX14
NETWORK
DRIVER
RN3
SH
LD
SH
LD
T
T
TB4
R
R
U14
NETWORK
LOOP
P5
ADD
P3
R24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
CX
6
CX1
U7
U1
X1
C3
C1
R3
CX7
Local
Local
24
V
A
C
(6
V
A
)
MiniLink
PD
Note:
S
e
e
P
a
g
e3&4O
f
This
Drawing
For
Optional
CommLink,
Computer
And
Remote
Link
Connection
Diagram.
Line
V
olt
age
24
V
A
C
(8
V
A
)
Connect
T
o
Other
V
A
V/Zone
Controllers
On
Loop
Connect
T
o
Other
V
A
V/Zone
Controllers
On
Loop
Connect
T
o
Other
V
A
V/Zone
Controllers
On
Loop
Power/Comm
Board
Power/Comm
Board
V
A
V/Zone
Controller
V
A
V/Zone
Controller
V
A
V/Zone
Controller
Line
V
olt
age
Line
V
olt
age
HV
AC
Unit
Controller
24
V
A
C
-
Size
T
ransformer
For
Required
V
A
Load
24
V
A
C
-
Size
T
ransformer
For
Required
V
A
Load
(1
MEG)
TB1
Connect
T
o
Modular
I/O
Connectors
Located
On
Back
Of
The
System
Manager
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
ST
A
TUS
SE
TPOINTS
SCHEDULES
AL
ARMS
OVERRIDES
Modular
System
Manager
Note:
A
M
odular
System
Manager
,
A
Modular
Service
T
ool
Or
A
P
C
W
ith
Prism
Sof
tware
Inst
alled
Can
B
e
Used
T
o
Program
And
Configure
The
Orion
System.
Note:
A
M
aximum
Of
6
V
A
V/Zone
Controllers
Can
Be
Connected
T
o
Each
Branch
Circuit.
A
tot
al
Of
16
Controllers
Are
Allowed
Per
Power/Comm
B
oard.
Use
Additional
Power/Comm
Boards
For
Systems
That
Exceed
16
Controllers.
See
The
V
A
V/Zone
Controller
Wiring
Diagram
For
Power/Comm
Board
T
ransformer
Sizing
And
Circuit
Design
Information.
1
1
1
0
0
0
PHILIPS
PHILIPS
PHILIPS
TB2
TB2
VAC
VAC
F1
F1
25
25
4A
4A
24
24
SHLD
SHLD
T
T
R
R
POWER
POWER
LD1
LD1
TB1
TB1
C1
C1
POWER & COMM
DIST. BOARD
YS101856
REV. 0
POWER & COMM
DIST. BOARD
YS101856
REV. 0
P5
P5
P4
P4
P3
P3
P1
P1
D1
D1
V1
V1
R1
R1
P2
P2
COMMP
IN
COMMP
IN
POWER
&
COMM
OUT
P
O
W
E
R&C
O
M
M
OUT
Modular
Service
T
ool
Mode
Selection
ENTER
CLEAR
ESC
PREV
NEXT
DOWN
UP
6
5
4
DEC
7
0
8
13
2
9
MINUS
-
ST
A
T
US
SE
TPOINTS
SCHEDULES
CONFIGURA
T
ION
AL
ARMS
ON
OVERRIDES
BAL
ANCE
-
TEST
Connect
T
o
Next
V
A
V/Zone
Controller
On
Branch
Circuit
Connect
T
o
Next
V
A
V/Zone
Controller
On
Branch
Circuit
SHLD
T
R
T
ypical
T
erminal
Blocks.
All
W
iring
T
o
Be
T
T
o
T
,
S
HLD
(G)
T
o
S
H
L
D(
G
)
&RT
oR
T
G
R
485LOOP
06/20/03
O-Network-SingleLoop1B.CDR
FILENAME
DA
TE:
B.
Crews
DESCRIPTION:
P
AGE
DRA
WN
BY
:
Wiring
&
C
onnection
Diagrams
JOB
N
AME
2o
f5
T
ypical
Sing
le
Loop
Netw
or
k
e
d
S
ystem
W
ith
MiniLink
P
olling
D
e
vice
Onl
y
Networked
System
-
Single
Loop