NewTek TriCaster Advanced Edition Automation and Integration Guide User Manual
Page 36
24 |
P a g e
6. Use the Restore Session Backup feature on the Home page of the remote system to open the backup
session file, and launch the session.
7. Re-launch the original session on the controlling system, and enable remote control over the second
system using the Options menu item as described earlier.
That does it as far as configuring TriCaster goes. Obviously too, though, mirroring normally calls for
upstream distribution amps to multiply camera feeds, attention to matching up audio routing, and so on.
Likewise, in most cases, attention must be given to output routing (and sometimes, ‘failover’ device
planning and connection).
In yet another approach to all of this, you might consider using an outboard network drive as the Session
Volume for both systems.
Note: Normally, TriCasters operating under remote control retain autonomous local control response. You can
actually enable bi-directional remote control by configuring two systems to control each other.
This can be especially useful in cases where different operators are responsible for specific aspects of the
production process.