beautypg.com

Tbar_value (double)[state: (double), Adjust_fxrate (double)[state: (double), Next_fxrate_preset (void) – NewTek TriCaster Advanced Edition Automation and Integration Guide User Manual

Page 154: Ftb_tbar_value (double)[state: (double), Ftb_auto (void)

background image

142 |

P a g e

_tbar_value (double)[state: (double)]

Description: Set the TBar location value.

Example:

Delay Shortcut

Value

main_tbar_value 50

_adjust_fxrate (double)[state: (double)]

Description: Adjust the FX rate, incrementing or decrementing based on Value.

Example:

Delay Shortcut

Value

main_adjust_fxrate 1

_next_fxrate_preset (void)

Description: Select the next Slow, Medium, or Fast preset.

Example:

Delay Shortcut

Value

main_next_fxrate_preset

ftb_tbar_value (double)[state: (double)]

Description: Manual fade to/from black on the program output (Output B). Value range between 0.0 and
100.0.

Example:

Delay Shortcut

Value

ftb_tbar_value 75

ftb_auto (void)

Description: Fade black on/off the program output (Output B).

Example:

Delay Shortcut Value

ftb_auto