beautypg.com

MovinCool CM25 Service Manual User Manual

Page 54

background image

Repair Section

54

LCD

displays

self-

diagnostic

codes.

E12

E14

4

Excessive current from

the STI module to the

compressor.

RESET the controller

*1

twice or three times. If

the error still occurs, replace the compressor.

E15

4

Compressor lock.

RESET the controller

*1

twice or three times. If

the error still occurs, replace the compressor.

E16

4

Compressor wires are

disconnected.

• Reconnect and check the compressor

wires.

• Reconnect and check the relay board

wires.

RESET the controller

*1

.

E17

4

Excessive compressor

load.

RESET the controller

*1

twice or three times. If

the error still occurs, replace the compressor.

Excessive compressor

startup differential

pressure.

E13

E18

4

Excessive current from

the power source to the

STI module.

RESET the controller

*1

twice or three times. If

the error still occurs, replace the compressor.

E19

4

Degraded heat sink

performance.

Replace the relay board.

Then initialize the fan motor. (See page 61.)

E20

4

Recovery from

momentary power loss or

momentary voltage drop.

Check if the supplied voltage to the unit is

unstable due to the external influence or not.

RESET the controller

*1

.

If the error still occurs, replace the relay

board.

Then initialize the fan motor. (See page 61.)

Momentary power loss,

or momentary voltage

drop.

E21

4

Sensor on the relay board

is short or open.

Replace the relay board.

Then initialize the fan motor. (See page 61.)

E22

4

Compressor actuating

circuit on the relay board

is short or open.

Replace the relay board.

Then initialize the fan motor. (See page 61.)

Condition

Check Area

Possible Cause

Remedy

Unit does

not

operate.

Self-Diagnostic

Codes

(WMC)

Buzzer

Pattern

User

Mode

Service

Mode

*1 : To RESET the controller, press RESET button, then press ON/OFF button.

This manual is related to the following products: