beautypg.com

Metro Mobile Computing Workstations MPS-4007 Lithium Ion Nano-Phosphate Power Supply User Manual

Page 39

background image

Metro

TM

MPS-4007 Li-Nano Power Supply Operations Manual Supplement, Doc. L01-505

39

InterMetro Industries Corporation

Removing the MPS-4007 Power Supply

Caution:

For safety, only qualified service personnel should perform the following procedure
to remove the MPS-4007 Power Supply from the Metro

TM

Mobile Computing

Workstations.

To remove the MPS-4007 Power Supply from the workstation base for replacement, perform the
following steps:

Notice: Save all handle brackets, screws and other hardware that are removed by this

procedure for the replacement power supply to be mounted on the workstation. If
replacement hardware is needed, please contact InterMetro Customer Service.

1.

Disconnect all cables: DC Power connector, RJ45 cable from the Gauge port, USB from
the USB-B port and AC cable. Remove the AC cable clamp from the ground stud on the
back of the power supply.

2.

Disconnect the batteries when shipping the power supply. See “Disconnecting the
Power Supply Batteries for Shipment” below.

3.

Remove the two 8-32 pan head screws from the workstation power supply mounts on
each side.

4.

Facing the back of the workstation, lift the power supply up to free the tabs from the slots
on the mounts on the bottom of the workstation base. Slide the handle brackets down
the ramp of the mounts and lift out the power supply.

5.

Remove the three 8-32 pan head screws from each of the two handle brackets on each
side of the power supply.

Notice: The handle bracket hardware must be removed and the batteries must be

disconnected before returning the power supply to InterMetro Industries Corporation.