PCI-DAS6071 User's Guide

Functional Details

19

A/D START TRIGGER signal

Use the A/D START TRIGGER signal for conventional triggering (when you only need to acquire data after a
trigger event). Figure 7 shows the A/D START TRIGGER signal timing for a conventionally triggered
acquisition.

Figure 7. Data acquisition example for conventional triggering

The A/D START TRIGGER source is programmable and may be set to any of the AUXIN inputs or to the
DAQ-Sync DS A/D START TRIGGER input. The polarity of this signal is also programmable to trigger
acquisitions on either the positive or negative edge.

The A/D START TRIGGER signal is also available as an output and can be programmed to appear at any of the
AUXOUT outputs. Refer to Figure 8 and Figure 9 for A/D START TRIGGER input and output timing
requirements.

Figure 8. A/D START TRIGGER input signal timing

Figure 9. A/D START TRIGGER output signal timing

The A/D START TRIGGER signal is also used to initiate pre-triggered DAQ operations (when you need to
acquire data just before a trigger event). In most pre-triggered applications, the A/D START TRIGGER signal
is generated by a software trigger. The use of A/D START TRIGGER and A/D STOP TRIGGER in pre-
triggered DAQ applications is explained next.

A/D Start Trigger

Start Scan

Convert

1

2

3

4

0

Scan Counter