2.10 $AAM
Description: Read Module Name
Command: $AAM[CHK](cr)
$
Delimiter character
AA
Address of reading module (00 to FF)
M
Command for read module name
Response:
Valid Command:
!AA(Data)[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax or communication error may get no response.
!
Delimiter for valid Command
?
Delimiter for invalid Command
AA
Address of response module(00 to FF)
(Data)
Name of module
Example:
Command: $01M
Receive: !017042
Read Address 01 module name, return name 7042.
Command: $03M
Receive: !037060D
Read Address 03 module name, return name 7060D.