9 $aaf – Measurement Computing CB-7000 DIO User Manual
Page 38
38
CB-7000 DIO Manual
2.9 $AAF
Description: Read Firmware Version
Command: $AAF[CHK](cr)
$
Delimiter character
AA
Address of reading module (00 to FF)
F
Command for read firmware version
Response:
Valid Command:
!AA(Data)[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax or communication error may get no response.
!
Delimiter for valid Command
?
Delimiter for invalid Command
AA
Address of response module(00 to FF)
(Data)
Firmware version of module
Example:
Command: $01F
Receive: !01A2.0
Read Address 01 firmware version, return version A2.0.
Command: $02F
Receive: !01B1.1
Read Address 01 firmware version, return version B1.1.