INSTRUCTION/INSTALLATION SHEET
lyriQ™ Standard Keypad
IS-0391 REV. E
©Copyright 2009 by Legrand All Rights Reserved.
Maximum Volume
Default (src 3, vol. All) is 100% of volume possible.
Limited Maximum Volume: (src 3, vol. 3 or 4) can be
adjusted down to 50% of total volume to limit the
loudest volume that the keypad will play at.
Default is used for normal operation and
environments.
Limited Maximum Volume is typically used for
small rooms such as a bathroom, bedroom and
in children’s rooms.
IR Target / IR Output
Disabled
Default (src 4, vol. 1) enables use of remote control
for Whole House commands and source equipment
control.
IR Output Disabled (src 4, vol. 2) enables in-room
keypad functions to be controlled by remote. Whole
House commands and source equipment control is not
available.
IR Target Disabled (src 4, vol 3) The keypad will not
respond to remote controls
Default - normal operation and environments
IR Output Disabled –for use when system is
installed in environments that have above
normal levels of radiated interference.
IR Target Disabled –for use when system is
installed in environments that have extreme
levels of radiated interference.
Nightlight
Default (src 1 & 3, vol. 1) Keypad glows dimly when
off.
Nightlight Disabled (src 1 & 3, vol. 2) Keypad
produces no light when off.
Default is used for normal operation and
environments.
Nightlight Disabled is used for those
customers that require absolute darkness in the
room when the Keypad is off.
Balance Setting
Default (src 1 & 2, vol. 3) is the middle of the range
Balance Adjustment (src 1 & 2, vol. 1,2,4,5) can be
adjusted greater or less to left and right channels
Default is used for normal operation and
environments
Balance Adjustment is used to accommodate
various user environments and to adjust sound
to listening position.
IR Repeat
Transmission
Default (src 1 & 4, vol. 2) is Multi-Burst Frequency
which is 40kHz and 56kHz.
IR Carrier Frequency at 40kHz
(src 1 & 4, vol. 1)
IR Carrier Frequency at 56kHz
(src 1 & 4, vol. 3)
Default is used for normal operation and
environments. The default will be effective for
the vast majority of source devices. Carrier
frequency can be changed if end user’s source
device does not respond to multi-burst.
IR Carrier Frequency Adjustments are
chosen based on end user’s remotes. (Most
devices are 40kHz. Cable and satellite boxes
are often 56kHz)