Is-0391 rev. e – Legrand AU7394-XX User Manual
Page 2
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 2 of 8
INSTRUCTION/INSTALLATION SHEET
lyriQ™ Standard Keypad
IS-0391 REV. E
©Copyright 2009 by Legrand All Rights Reserved.
A. “Rough-in”
steps:
1) A single Category 5 cable should be run from the enclosure location to a single gang outlet box or mud
ring at each Volume Control location.
NOTE: We also recommend running a 16/4 speaker wire along with the Category 5 cable to support
future upgrades to High Performance Keypads if desired.
B. “Trim-out”
steps:
1) Connect the volume control by terminating the pre-wired Category 5 cable from the enclosure with an
RJ45 plug, following the T568A wiring standard and insert this plug into jack J1 (see Figure 2).
2) For the Line Out/Speakers Out connections (TB1/TB2) strip 3/8” of insulation from each of the four
conductors and insert the appropriate wires into the appropriate connections (see Figure 2).
NOTE: Polarity and channels are clearly marked (L+, L-, R-, R+) for proper identification during
installation.
a) Use TB2 to connect one pair (only) of 8 ohm evōQ™ audio speakers to the volume control.
b) Use TB1 to connect your evōQ™ powered sub-woofer or an external amplifier to the volume control.
These connection terminals do not provide any amplification but the volume control on the keypad
controls the output level of this connection.
3) Connections in the enclosure (see Figure 3):
a) The Category 5 cable that was run to each volume control location should be terminated with an RJ45
plug according to the T568A wiring standard and inserted into one of the zone output jacks of the
associated lyriQ™ audio distribution module.
Figure 3