K-Patents PR-01-S User Manual
Page 49

INSTRUCTION MANUAL FOR K-PATENTS PR-01-S (-AX/FM/CS)
DOCUMENT/REVISION No. INM 1/14
Effective: May 15, 2009
47
Code
Diagnostic message
Cause
0
Normal operation
No fault
0
In divert control operation
No fault
0
Removed from divert control
No fault
Process related faults
Priority Code
Diagnostic message
Cause
1
1
Retrying wash
Prism wash attempt failed
2
2
Solids warning
Solids below warning limit
3
3
Solids alarm
Solids below alarm limit
4
23
Wash stop / Temp. limit
Temperature below set limit
5
4
Low concentration / no sample
Whole image bright
6
6
High process temperature
Temperature above set limit
7
21
Low light intensity
Image nearly dark
8
22
Dip in image
Optical image not correct
9
7
High conc / prism coated
No shadow edge in image
Equipment malfunctions
Priority Code
Diagnostic message
Cause
10
28
Wash stop / ext. stop
Input switch activated for wash stop
11
5
Prism wash failure
Wash fault after retries
12
8
External output failure
No response from output unit
13
9
Relay unit fault
No response from relay unit
14
10
Divert control fault
No response from divert unit
15
11
Temperature measurement fault
Temperature out of limits
16
12
Prism coated / LED fault
Light intensity too low
17
13
Not in line
In line switch contacts open
18
24
High internal humidity
Sensor internal humidity too high
19
25
High internal temperature
Sensor internal temp too high
20
14
Detector timeout
No signal from image detector
21
15
Sensor transmission error
Noisy signal from sensor
22
16
No sensor signal
No signal from sensor
23
17
Wrong concentration parameters Makes R.I. outside range
24
18
Constants error
Wrong EPROM parameters
25
19
Sensor interface fault
Fault on processor card
26
20
EEPROM write error
Fault on processor card
Phase codes
Code
Diagnostic message
Cause
0 Blank
Normal
operation
1
Wait
Wash permit wait
2 Precondition Preconditioning
3
Precondition
Precondition / wash wait
4 Wash
Wash
5
Recovery
Recovery from wash
6
Hold
Hold after external wash
Table 6.30
PR-01-S messages.