2 fiber, Fiber, Specifications – IHSE USA 482 Series Draco vario Dual- Head User Manual
Page 59
Specifications
2013-12-06
59
7.2.2 Fiber
A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Switches or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of cable
Specifications
Single-mode 9μm
Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout cable)
I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Multi-mode 50μm
Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-mode 62.5μm
Two fibers 62.5μm
I-V(ZN)HH 2G62,5 (in-house breakout
cable)
A/DQ(ZN)B2Y
4G62,5
(outdoor cable,
with protection against rodents)
Maximum Acceptable Cable Length
Type of cable
Maximum Acceptable Cable Length
Single-mode 9μm
10,000 m (32,800 ft)
Multi-mode 50μm (OM3) 1,000 m (3,280 ft)
Multi-mode 50μm
400 m (1,300 ft)
Multi-mode 62.5μm
200 m (650 ft)
If you use single-mode SFPs with multi-mode fibers, you normally can
double the maximum acceptable cable length.
Pos: 80 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL)_Steckverbinder 477-xx @ 5\mod_1278954447542_6.doc @ 43740 @ @ 1
Type of Connector
Connector
LC Connector
Pos: 81 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1