Operation, Metric, English – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 98: Aluminum – gouging 200 amps, H35 plasma / n, Shield

MAX200
Instruction Manual
4-33
15
OPERATION
49-51
50-52
50
120
120
3.4-3.5
3.4-3.6
3.4
8.3
8.3
Shield
Gas Inlet
Pressure
(psi)
TEST
(psi)
RUN
(psi)
Shield
Gas Inlet
Pressure
(bar)
TEST
(bar)
RUN
(bar)
Metric
Plasma Gas Pressure
Shield
Gas
Pressure
(bar)
Plasma
Gas Inlet
Pressure
(bar)
English
Plasma Gas Pressure
Shield
Gas
Pressure
(psi)
Plasma
Gas Inlet
Pressure
(psi)
Aluminum – Gouging
200 amps
•
H35 Plasma / N
2
Shield
Hypertherm recommends a mixture of 35% hydrogen and 65% argon for the plasma gas.
020485
Shield
020615
Nozzle
020423
Retaining cap
220021
Electrode
020607
Swirl ring
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.