Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 90: Aluminum – above water 100 amps, Air plasma / air shield

MAX200
Instruction Manual
4-25
14
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
1/8
3/32
2.5
135
110
2800
0.0
3/16
1/8
3
140
90
2290
0.5
1/4
1/8
3
145
70
1780
0.5
3/8
1/8
3
145
50
1270
0.5
1/2
1/8
3
150
40
1010
*
5/8
.16
4
155
30
760
*
3/4
3/16
5
160
25
635
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
3
2.5
3/32
135
2800
110
0.0
5
3
1/8
140
2290
90
0.5
6
3
1/8
145
1780
70
0.5
10
3
1/8
145
1270
50
0.5
12
3
1/8
150
1010
40
*
15
4
.16
155
760
30
*
20
5
3/16
160
635
25
*
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
37
22-26
54-58
270
60
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
17
1.5-1.8
3.7-4.0
127
4.0
Aluminum – Above Water
100 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.
020448
Shield
020611
Nozzle
120837
Retaining cap
120547
Electrode
020607
Swirl ring