Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 85: Stainless steel – above water 200 amps, Plasma / air shield

4-20
MAX200
Instruction Manual
14
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
3/16
1/8
3
125
135
3430
0.0
1/4
1/8
3
130
120
3050
0.5
3/8
1/8
3
130
100
2540
1.0
1/2
1/8
3
135
75
1900
2.0
5/8
.16
4
140
60
1520
2.0
3/4
3/16
5
140
45
1140
2.5
7/8
1/4
6
145
35
890
2.5
1
1/4
6
150
20
510
*
1-1/4
1/4
6
160
15
380
*
1-1/2
1/4
6
160
10
250
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
5
3
1/8
125
3430
135
0.0
6
3
1/8
130
3050
120
0.5
10
3
1/8
130
2540
100
1.0
12
3
.16
135
1900
75
2.0
15
4
.16
140
1520
60
2.0
20
5
3/16
140
1140
45
2.5
25
6
1/4
150
510
20
*
32
6
1/4
160
380
15
*
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
60
34-38
50-54
270
60
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
28
2.3-2.6
3.4-3.7
127
4.0
Stainless Steel – Above Water
200 amps
•
N
2
Plasma / Air Shield
This gas combination is used when cut edge quality, surface nitriting and surface oxidation of alloying
elements are less important. Electrode life is extended when this combination is used.
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 7/8 inch (21 mm) not recommended.
020424
Shield
020608
Nozzle
120837
Retaining cap
020415
Electrode
020607